78, Jalan Pasar, Pudu,
55100 Kuala Lumpur,
Malaysia.
+6012-716 1623
+603-9221 0207
+603-9221 8927
+603-9221 0207
+603-9221 8927
+603-9221 0819

| Previous | 5 / 12 | Next |
| 1 = Jacket: | PVC, max Ø 3.8 x 7.6 mm, black | |
| 2 = Shield No 1: | 68 tinned LCOF copper wires (0.10 mm) 100% coverage | |
| 3 = Shield No 2: | 68 tinned LCOF copper wires (0.10 mm) 100% coverage | |
| 5 = Insulation (cond.): | PE, semiconductive black | |
| 6 = Conductor: | Stranded tinned LCOF copper wires 7 x 0.16 mm (0.14 mm²) 7x34AWG = 26 AWG | |
Technical Datas: |
||
| Conductor resistance: | < 140 ohm/km | |
| Shielding resistance: | < 22 Ohm/km | |
| Capacitance cond/shield: | < 57 nF/km | |
| Insulation reslstance: | > 200 MOhm/km | |
| Chararteristic impedance: | 75 Ohm@200MHz | |
| Test voltage: | 1000 V eff. C/S | |
| Temperature range: | flexi-installed: | -5° to +50° C |
| fix-installed: | -30° to +70° C | |